The 5-minute average air temperature at a height of 1.5 meters above the ground.
Type | Sensor Used | Standards Units | Accuracy |
Standard - Primary | RM Young 41342 Platinum RTD Probe 2017-Present; Thermometrics Air Temperature 2004-2017; PDF Vaisala HMP35C 1994-2003 | degrees Celsius | ± 0.5 °C |
RM Young 41342 Platinum RTD
Same sensor as TAIR but positioned at 9 meters above ground level.
Type | Sensor Used | Standards Units | Accuracy |
Standard - Secondary | RM Young Platinum RTD Probe 2015-Present; Thermometrics Air Temperature, PDF; 1994-2015 | degrees Celsius | ± 0.5 °C when windspeed is > 6 m/s |
± 1.0 °C when windspeed is 3 - 6 m/s | |||
± 1.5 °C when windspeed is 2 - 3 m/s | |||
±3.0°C when windspeed is 1 - 2 m/s |
RM Young 41342 Platinum RTD
Not measured, but computed from the 1.5 meter air temperature and relative humidity.
Sensor Used | Standard Units |
Thermometrics Air Temperature (for Air Temperature), PDF | degrees Celsius |
Vaisala HMP45C (for Relative Humidity), PDF |
Not measured, but computed from the 1.5 meter air temperature and the wind speed at 10 meters.
Sensor Used | Standard Units |
Thermometrics Air Temperature (for Air Temperature), PDF | degrees Celsius |
RM Young Wind Monitor (for Wind Speed), PDF |